Hi Mohan
Yes this is possible, via configuration of the Serial Number Profile in the IMG. For each business procedure (eg: GR, create delivery) within your profile you can define whether an equipment is created by default, or not.
Config for this is in tcode OIS2. Set the "EqReq" field to 01 for each procedure within your profile where you don't want an equipment created.
Regards